• TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm
  • TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm
  • TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm
  • TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm
  • TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm
  • TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

Type: Insulated
Conductor Type: Stranded
Application: Signal and Low Voltage Power
Conductor Material: Copper
Sheath Material: TPU/TPE/PVC/Silicone Rubber Optional
Insulation Material: PE
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
AE208X1+7
Material Shape
Round or Flat Optional
Range of Application
Medical Field
Certification
ISO9001, CE, RoHS, ISO13485
Brand
Yqf
Feature
Reusable
Conductor
Tinned Copper
Jacket
TPU
Shield
Tinned Copper
Fast Prototype
2-5 Days
Diameter
5.8mm+-0.15mm
Transport Package
Standard Export Carton or Customized
Specification
60*42*0.035
Trademark
YQF
Origin
China
HS Code
8544422100
Production Capacity
80000km

Product Description

TPU 5040 Medical cable durable 8 core Coiled  Branch AED pad cable 1x 22 AWG +7x 26 AWG OD 5.8 mm

(Free Design)


 

Defibrillator Coil & Defibrillator Wire

Defibrillator wires have 3 main forms:Coil & Round;Straight & Round and Flat Ribbon.The most used is Coil cord for AED paddle,and Flat Ribbon cable for AED Pad. 

The Defibrillator cable usually contains 3 to 10 depends on its purpose and applications. A simple 3 wire defibrillator (it could be a  aed training machine) only need 3 wires for the paddle. And ECG Defibrillator will use 4-8 signal wire to get ECG signal,indicates the operator if it is necessary to make difibrillation and when to make it. The more Intelligent a  ECG Monitor with defibrillator is,the more wires it need.ECG Defibrillator monitor the heart and indicates the operator when is the best time to defibrilate and how many joules power is needed.It make defibrillation easier and more accurate.

As a China Medical cable manufacturer ,we custom AED cable ( AED leads) to interconnect between its power unit and the patient paddle or Pads according to customer,s requirement

 AED electrode pads become a mainstream,compared with Paddles,AED Pads/Gel are used to reduce transthoracic impedance when paddles are applied directly to the chest wall to deliver a shock. Better protective for patients and doctors. Especially with Mindray intellectual AED, an un-trained person can also make an emergency rescue under the guide of the defibrillators' screen and voice 


 

AED Cable has 1 or 2 17AWG-22 AWG wires can bear 5000V AC voltage and 3-8 wires for Signals transition.Round Coiled Extension cord and Flat Bulk Cable are the two main forms.

Coiled Extension cord for Defibirllator adopts TPU as Jacket. As for insulation,when extreme high voltage such as 8000V AC ,is needed,and also need the cable to be thin,then Teflon (FEP,PFA PTFE) is used.

Welcome Ask for sample or custom solution:

Technical Specification

 
Item   (specification)
conductor Material Tinned copper + Kevlar(1c) Tinned copper +Kevlar (7c)
specification 165/0. 05TC + 30/0. 05TSN + 200DKevlar 30/0. 08TC + 200DKevlar
Twisted gauge 22AWG 26AWG
Complete diameter 0.80MM 0.51MM
insulation Material TPE PP
thickness 0.6 0.17
diameter 2. 0 ± 0.05  0.85 ± 0.03
colour red 7 different colors
Cabling Material Tissue paper + 1500Dkevlar
Wrap thickness 0.05MM
Overlap rate 50%
Jacket Material TPU (BASF Elastollan 1185AM)
thickness 1
diameter 5.80 ± 0.20
colour TBD
Performance requirements: 
1. Resistance requirements: 22AWG-53.9Ω MAX 26AWG - 131Ω MAX 
2. High voltage resistance: core wire 1 and core wire 2, core wire and sheath resistant to DC4000V / 60S, leakage current 0.008mA / MIN 3, DC500V Insulation above 500M0 (test sample line 1 ~). 
4. load bending test: 
4.1. After bending 10000 times (+/- 90 ", 30 times / mmn 5000 times, rotating 90" around the axis, hanging weight 500g) , 10% of the strands cannot be broken. 
4.2. After bending 100000 times (+/- 90 ", 30 times / mmn 50000 times, rotating 90" around the axis and hanging weight 500g), the core wires are continuous. 
5. Appearance Requirements: smooth appearance, no defects, unevenness.
 



Other Coiled Cable for Defibrillator as following:




TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

Your may also interested in following medical grade cables

Single lead to 18 leads cable for ECG Monitoring System as following:

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

Coaxial Low Triboelectrical Noise Cable for micro signal devices,including ECG monitor

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

1P+2C/3C/4C/5C/6C/7C for Spo2 Extension Cable

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

Acocording to different Sterrilization Method or Chemical or Physical Properties,we provide different materials for options:
 
Conductor Options Shielding Options Enhancement Options Insulation & Jacketing Materials
Bare Copper Bare Copper Braid Strength Members CPE/Chlorinated Polyethylene PFA/Perfluoroalkoxy
Tinned Copper Tinned Copper Braid Water Blocking EPDM/Ethylene Propylene Diene Monomer PFE/Perfluoroelastomer
Silver Plated Copper Silver Plated Copper Braid Fillers ETFE/Ethylene Tetrafluroroethylene PP/Polypropylene
Nickel Plated Copper Nickel Plated Copper Braid Rods FEP/Fluorinated Ethylene PTFE/Polytetrafluoroethylene
High Strength Alloys High Strength Alloys Braid Tubes Foamed FEP PUR/Polyurethane
Copper Clad Steel Copper Clad Steel Braid   Foamed PFA PVC/Polyvinyl Chloride
Prebonded Conductor Stainless Steel Braid   Foamed PE Silicone
Overcoated Conductor Aluminum Mylar Foil Shield   Foamed TPE Tefzel
Topcoated Conductor Spiral Shield   Halar TFE/Tetrafluoroethylene
      HDPE & LDPE TPE/Thermoplastic Elastomer
      Hytrel TPR/Thermoplastic Rubber
      mPPE/Modified Polyphenylene XLPE/Cross-Linked Polyethylene
      Neoprene XLPO/Cross-Linked Polyolefin
      PE/Polyethylene  
 

 

Custom Medical Cable Manufacturer -3 Key Factors To Make Your Choice
To choose a reliable custom medical cable manufacturer is critical to a medical device manufacturer. When you are making a choice, there are 3 factors you have to consider:
 

First,Are They An Experienced Medical Cable Manufacturer?

Working with a experienced medical cable expert is critical if you want to keep your medical devices running safely, functionally and durable. A medical cable manufacturer must be ISO 13485 certified. This is the most direct way you can make a rough judgment how many years they have engaged in medical
cable. But this is not totally reliable, some cable manufacturers would like to apply all types of certifications when then founded the company.

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mmTPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm

An experienced medical cable factory
usually will ask you following questions when you make an inquiry if you did not give them your exact requirement:
  •  What medical device will the medical cable be applied to/used for?
  1. What is the acceptable OD(out diameter)and tolerance of the cable
  2. What is the gauge of each wire? Or how many strands of specific conductor you would like each wire to be
  3. Where is the medical device being used (i.e. X-ray room, doctor's office, Ambulance, operating room, etc.)?
  4. Do you prefer disposable medical cable or reusable cable?
  5. What are your sterilization methods (chemicals or physical? What are the chemical sterilization materials? What is the
    temperature, pressure, Ray (Ultraviolet, note: X-ray not used for sterilization)?  
  6. Will the medical cable be exposed to any other chemicals or fluids? Will there be any extra coat to protect the cable?
  7. What is the contacting level between the cable and patient (i.e. absolutely no contact, occasional contact, always
    contact, implanted, etc. This relates to biocompatibility and material choosing)?
  8.   Do you have any supplementary requirements (such as, UL94 Level/framing rate, temperature resistant,ultra-flexible, Matt or Glossy, coiling etc.)?

 Second:what Are Their Producing Equipment And Laboratory Testing Devices?

Medical cable manufacturing has much more processing procedures than normal cable. And in most situation, it demands the conductors to be as thin as possible. For the
same gauge cable, thinner conductor will make it more flexible and better electronic performance. Not all conductor stranding machine can strand thin conductors as they are easy to break.so the precision level can determine the quality of the wire in some way besides of staff expertise. For testing devices, without the right testing devices, you cannot make related testing, such as RoHS,High Frequency,Triboelectric noise ,Tensile…(please refer to our Lab)

 

  Third:Strategic Partners

For most industries, Partners belongs to commercial secret. For medical cable field, medical devices manufactures has a AVL(approved vendor list),similar to UL in some way. If a medical cable manufacturer is in the AVL of many worldwide famous brands,this is the easiest way for you to choose it as your potential partner too. YQF
has be a partner for many famous brands and in their AVL for many years,contact us for trading reference if you are making medical cable supplier.



Performance Requirement:
 
1,High pressure resistance: AC 1500V, leakage current 0.25Ma/Min DC5000V,the leakage current less than 0.25mA,no breakdown
2,Insulation resistance:DC500V,(1M) the resistance are more than 10000M
3, Bending test: loading 800g,±90°40times/min more than 5000time
4,Conductor resistance: < 0.239Ω/M





Our  Advantage:
 

1, We are manufacturer of more than 16years' experience, produce all the products displayed in our website.Providing OEM/ODM service
2,Free samples available with 3days delivery
3,Certifications: ISO9001:2008,ISO13485-2003  ISO14001-2004

4Warranty: 12months for reusable SPO2 sensor cable,6months for ECG cables
5,Top-quality,non-toxic, anti-interference,soft and durable TPU cable
6, Excellent skilled staffs with professional product knowledge and high work efficiency to solve your any problems within 6hours.
7,strictly testing before packing and shipping:
1) 1.Bending testing 
2).Resistance testing   
3).Capacitance testing                                         
4).Dielectric strength testing
5).Aging testing
6).Low noise testing 

A leading manufacturer of customized wires and cables
1,Focus on Cable R&D and Manufacturing for 16 years
2,Annual output: 80,000KM ,round the Earth for 2 circle
3, ISO 9001,ISO13485,ISO14001 certified
4,Repeated order rate:100%
5,30% of our partners have been working with us for 10 years

Products Certificates We have

TPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mmTPU 5040 Medical Cable Durable 8 Core Coiled Branch Aed Pad Cable 1X 22 AWG +7X 26 AWG Od 5.8 mm









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now