• High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
  • High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
  • High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
  • High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
  • High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
  • High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable

High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable

Type: Insulated
Conductor Type: Stranded
Application: Signal and Low Voltage Power
Conductor Material: Copper
Sheath Material: TPU TPE PVC and Silicone Rubber Optional
Insulation Material: PE
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YQF-ES001-01
Material Shape
Round and Flat Optional
Range of Application
Medical Field
Certification
ISO9001, ISO 13485 ISO10993
Brand
Yqf
Conductor
Silver Plating
Jacket
Silicone
Shield
Tinned Copper
Transport Package
Standard Export Carton or Customized
Specification
60*42*0.035
Trademark
YQF
Origin
China
HS Code
8544422100
Production Capacity
8000km

Product Description


High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable
 

Silicone Rubber Cable Applications In Medical


No matter it is Class 1, Class 2, or Class 3 medical devices or accessories, Silicone cable application can be found everywhere. Sterilization and Biocompatibility are prior concerns .As mentioned in silicone cable properties, it is clear that SiHF silicone cable   is absolutely an ideal choice for medical applications. Such as monitoring system sensor, robotic arms, imaging system, Spo2 sensor, ECG/EKG,High-End ESU(Electrosurgical Unit)

 

Five Factors Decides The Electrosurgical Performance On The Target Tissues

  • the time in contact with the tissue;
  • the intensity of the current;
  • the frequency of the current;
  • the waveform of the current;
  • and the electrode size.
  • If these factors are well regulated, the surgeon can excise tissue with minimum damage while allowing for adequate histologic evaluation. The more advanced ESUs have microprocessors that adjust power output to maintain a constant preset level; as tissue resistance changes during the procedure, the output is automatically varied to maintain a uniform cut.

3 Types Of Variable Current Settings In Modern ESU

The Latest ESU(Electrosurgical Unit) offer three variable current waveforms settings: 

  1. cutting
  2. blended cutting
  3. coagulation

A continuous, high-frequency current provides for pure cutting,

A short, interrupted bursts of current is intended for Coagulation.

Combining this two forms of currents will produces a blended effect that allows for both efficient cutting and limited coagulation to control bleeding. The frequency varies from 500,000 to 4,000,000 cycles/sec.

 

The Benefits Of ESU Compared With Traditional Surgical Method

ESUs are generally maintenance-free, and are relatively inexpensive compared with laser units and cold-knife.


High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable


Company information:
High Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu CableHigh Frequency Silver Plating Conductor Silicone Jacket Cable for Reusable Esu Cable








Performance Requirement:
 
1,High pressure resistance: AC 1500V, leakage current 0.25Ma/Min DC5000V,the leakage current less than 0.25mA,no breakdown
2,Insulation resistance:DC500V,(1M) the resistance are more than 10000M
3, Bending test: loading 800g,±90°40times/min more than 5000time
4,Conductor resistance: < 0.239Ω/M


Our  Advantage:
 

1, We are manufacturer of more than 16years' experience, produce all the products displayed in our website.Providing OEM/ODM service
2,Free samples available with 3days delivery
3,Certifications: ISO9001:2008,ISO13485-2003  ISO14001-2004

4Warranty: 12months for reusable SPO2 sensor cable,6months for ECG cables
5,Top-quality,non-toxic, anti-interference,soft and durable TPU cable
6, Excellent skilled staffs with professional product knowledge and high work efficiency to solve your any problems within 6hours.
7,strictly testing before packing and shipping:
1) 1.Bending testing 
2).Resistance testing   
3).Capacitance testing                                         
4).Dielectric strength testing
5).Aging testing
6).Low noise testing 

A leading manufacturer of customized wires and cables
1,Focus on Cable R&D and Manufacturing for 16 years
2,Annual output: 80,000KM ,round the Earth for 2 circle
3, ISO 9001,ISO13485,ISO14001 certified
4,Repeated order rate:100%
5,30% of our partners have been working with us for 10 years









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now